{"product_id":"daikin-9000-btu-16-seer2-single-zone-concealed-duct-mini-split-heat-pump-system-r32-230v","title":"Daikin 9,000 BTU 16 SEER2 Single Zone Concealed Duct Mini Split Heat Pump System - R32 | 230V","description":"\u003ch3\u003eDaikin 9,000 BTU 16 SEER2 Single Zone Concealed Duct Mini Split Heat Pump System - R32 | 230V\u003c\/h3\u003e\n\u003cp\u003eThe Daikin 16 SEER2 Single Zone Concealed Duct Mini Split Heat Pump System is a 9,000 BTU (nominal) R-32 heat pump with a concealed horizontal-duct indoor unit and an inverter outdoor unit. The indoor unit installs above a ceiling and connects to short duct runs, so only the grilles are visible in the room.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003e9,000 BTU Nominal Capacity\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– Rated cooling 9,000 BTU\/h (4,400–9,400) and rated heating 10,900 BTU\/h (4,400–12,800).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e16.0 SEER2 Energy Efficiency\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– 11.1 EER2 and 9.0 HSPF2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAdvanced Inverter Technology\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– Inverter-controlled swing compressor for variable-capacity heating and cooling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCooling \u0026amp; Heating Functionality\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– Cooling operation 50°F to 114.8°F; heating operation -13.8°F to 64.4°F. Low-temperature cooling down to -4°F with an optional wind baffle and field settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQuiet Concealed Duct Indoor Unit\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– Indoor sound pressure as low as 32 dB(A). Rated external static pressure 0.20 in. WG, adjustable from 0.12 to 0.60 in. WG in 13 stages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironmentally Friendly R-32 Refrigerant\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– Factory charged for up to 49-1\/4 ft of line set.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConcealed Duct Indoor Unit\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– Slim 9-5\/8 in. tall horizontal-duct air handler hidden above the ceiling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e230V Power Supply\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e– 208-230 V, 60 Hz, 1-phase.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eIdeal Applications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRooms or multi-room zones where a wall-mounted indoor unit is not desired.\u003c\/li\u003e\n\u003cli\u003eRenovations and new construction that can use short supply and return duct runs.\u003c\/li\u003e\n\u003cli\u003eSpaces that need a hidden indoor unit with only grilles showing.\u003c\/li\u003e\n\u003cli\u003eProjects that require professional installation of a ducted mini-split system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eWhat's Included:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor Concealed Duct Unit (FDMA09AVJU9)\u003c\/li\u003e\n\u003cli\u003eOutdoor Condenser Unit (RXP09AVJU9)\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eChoose Line Set Length\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA wired remote controller (BRC1NRV71) is optional and is not included. An air filter is not a standard accessory and must be installed in the return duct (dust collection efficiency of 50% or more).\u003c\/p\u003e\n\u003ch4\u003eWarranty:\u003c\/h4\u003e\n\u003cp\u003eDaikin provides a\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e12-year limited parts and compressor warranty\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003ewith online registration. Commercial applications have a 5-year limited parts warranty.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCondenser Specs:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tr-title\"\u003e\n\u003cth class=\"border-left\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"border-right\"\u003eSpec\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"SKU\"\u003eRXP09AVJU9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Weight\"\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Manufacturer\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCooling BTU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Cooling BTU\"\u003e9,000 (rated; 4,400–9,400)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHeating BTU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Heating BTU\"\u003e10,900 (rated; 4,400–12,800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDecibel Level (dBA)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Decibel Level (dBA)\"\u003e50 (cooling) \/ 52 (heating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Refrigerant\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSEER2\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"SEER2\"\u003e16.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eEER2\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"EER2\"\u003e11.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCompressor Type\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Compressor Type\"\u003eSwing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eLiquid Line\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Liquid Line\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSuction Line\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Suction Line\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Electrical\"\u003e208-230 V | 60 Hz | 1 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMax Breaker Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Max Breaker Size\"\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin. Breaker Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min. Breaker Size\"\u003e11.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBTU\/Tonnage\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"BTU\/Tonnage\"\u003e9,000 BTU\/0.75 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin\/Max Outdoor Temp for Heating\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min\/Max Outdoor Temp for Heating\"\u003e-13.8°F to 64.4°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin\/Max Outdoor Temp for Cooling\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min\/Max Outdoor Temp for Cooling\"\u003e50°F to 114.8°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMax Line Set Length\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Max Line Set Length\"\u003e65-5\/8 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMax Height Difference\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Max Height Difference\"\u003e49-1\/4 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eZone Compatibility\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Zone Compatibility\"\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Height\"\u003e21-15\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Width\"\u003e26-9\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDepth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Depth\"\u003e11-3\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Warranty\"\u003e12-year limited parts and compressor warranty with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSafety Information\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Safety Information\"\u003e\u003ca\u003ePROPOSITION 65 WARNING\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eAir Handler Specs:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"tr-title\"\u003e\n\u003cth class=\"border-left\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"border-right\"\u003eSpec\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"SKU\"\u003eFDMA09AVJU9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Weight\"\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Manufacturer\"\u003eDaikin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHSPF2\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"HSPF2\"\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDecibel Level (dBA)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Decibel Level (dBA)\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Refrigerant\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMini Split Type\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Mini Split Type\"\u003eConcealed Duct\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eAirflow Rate (H\/M\/L)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Airflow Rate (H\/M\/L)\"\u003e401 \/ 338 \/ 279 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eExternal Static Pressure\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"External Static Pressure\"\u003e0.20 in. WG standard (adjustable 0.12–0.60)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eZone Compatibility\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Zone Compatibility\"\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Height\"\u003e9-5\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Width\"\u003e27-9\/16\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDepth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Depth\"\u003e31-1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Warranty\"\u003e12-year limited parts and compressor warranty with online registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSafety Information\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Safety Information\"\u003e\u003ca\u003ePROPOSITION 65 WARNING\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eManuals \u0026amp; Documents\u003c\/h4\u003e\n\u003cp\u003e\u003ca data-pdf-native=\"true\" href=\"https:\/\/daikincomfort.com\/docs\/default-source\/fdma\/em-fdma_avju9-rxp_avju9.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Engineering Data\"\u003eEngineering Data\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca data-pdf-native=\"true\" href=\"https:\/\/daikincomfort.com\/docs\/default-source\/fdma\/im-cdma-fdma_avju9.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Indoor Installation Manual\"\u003eIndoor Installation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca data-pdf-native=\"true\" href=\"https:\/\/daikincomfort.com\/docs\/default-source\/fdma\/im-rxp-09-12-avju9.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Outdoor Installation Manual\"\u003eOutdoor Installation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca data-pdf-native=\"true\" href=\"https:\/\/daikincomfort.com\/docs\/default-source\/fdma\/om-cdma-fdma_avju9.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Operation Manual\"\u003eOperation Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca data-pdf-native=\"true\" href=\"https:\/\/cdn.daikincloud.io\/PIM\/Assets\/Documents\/WGS-FDMA_AVJU9-RXP_AVJU9.pdf\" target=\"_blank\" rel=\"noopener\" title=\"Guide Specifications\"\u003eGuide Specifications\u003c\/a\u003e\u003c\/p\u003e\n","brand":"Daikin","offers":[{"title":"None","offer_id":68067849568569,"sku":"RXP09AVJU9 \/ FDMA09AVJU9","price":3086.44,"currency_code":"USD","in_stock":true},{"title":"25 Ft","offer_id":68067849601337,"sku":"RXP09AVJU9 \/ FDMA09AVJU9","price":3202.44,"currency_code":"USD","in_stock":true},{"title":"35 Ft","offer_id":68067849634105,"sku":"RXP09AVJU9 \/ FDMA09AVJU9","price":3282.44,"currency_code":"USD","in_stock":true},{"title":"50 Ft","offer_id":68067849666873,"sku":"RXP09AVJU9 \/ FDMA09AVJU9","price":3392.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0292\/1336\/0188\/files\/daikin-concealed-duct-9k.jpg?v=1794522496","url":"https:\/\/chillminisplits.com\/es\/products\/daikin-9000-btu-16-seer2-single-zone-concealed-duct-mini-split-heat-pump-system-r32-230v","provider":"Chill Mini Splits","version":"1.0","type":"link"}