{"product_id":"aciq-3-ton-36-000-btu-16-1-seer2-high-efficiency-central-heat-pump-inverter-r454b-3-ton-36-000-btu-central-ducted-air-handler-r454b","title":"ACiQ 3 Ton (36,000 BTU) 16.1 SEER2 High Efficiency Central Heat Pump | Inverter – R454B \u0026 3 Ton (36,000 BTU) Central Ducted Air Handler – R454B","description":"\u003ch1\u003eACiQ 3 Ton (36,000 BTU) 16.1 SEER2 High Efficiency Central Heat Pump | Inverter – R454B \u0026amp; 3 Ton (36,000 BTU) Central Ducted Air Handler – R454B\u003c\/h1\u003e \u003chr\u003e \u003ch2\u003eOverview\u003c\/h2\u003e \u003cp\u003eThe ACiQ 3 Ton Heat Pump System pairs the robust ACIQ-36-EHPD inverter condenser with the versatile ACIQ-36-AHD multi-positional air handler to deliver precise, efficient heating and cooling through your existing ductwork. Variable-speed inverter technology lets the compressor modulate its output between 12,000 and 36,000 BTU to exactly match demand—eliminating short-cycling and cutting energy waste.\u003c\/p\u003e \u003cp\u003eOn first startup, the “learning condenser” enters sensor-driven mode to collect indoor\/outdoor temperatures, duct pressures, and refrigerant data, then optimizes future operation for maximum efficiency. Rated for −13 °F to 122 °F in cooling and down to 5 °F in heating, it maintains quiet, reliable comfort even in extreme climates.\u003c\/p\u003e \u003cp\u003eBacked by a 12-year compressor warranty and 7-year parts coverage (online registration required), this whisper-quiet system (63 dBA outdoor, up to 48 dBA indoor) integrates with any 24 V thermostat and can be installed upflow, downflow, or horizontally.\u003c\/p\u003e \u003chr\u003e \u003ch2\u003eHow is it different from a traditional heat pump?\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eVariable BTU inverter:\u003c\/strong\u003e automatically adjusts output from 12,000–36,000 BTU\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSmart soft-start:\u003c\/strong\u003e reduces inrush current and energy waste\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHeating-sized design:\u003c\/strong\u003e size for heat without short-cycling in cooling mode\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCold-climate rating:\u003c\/strong\u003e efficient heating down to 5 °F outdoor\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch2\u003eQuick Facts\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eOutput: 12,000–36,000 BTU (cooling \u0026amp; heating)\u003c\/li\u003e \u003cli\u003eRefrigerant: R454B\u003c\/li\u003e \u003cli\u003eSEER2 \/ HSPF2: 16.1 \/ 8.7\u003c\/li\u003e \u003cli\u003eOperating range: −13 °F to 122 °F (cooling); −13 °F to 75 °F (heating)\u003c\/li\u003e \u003cli\u003eDurable gold-fin coil coating\u003c\/li\u003e \u003cli\u003eQuiet operation under full load\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eUse our sizing calculator (\u003ca href=\"\/pages\/hvac-load-calculator\" rel=\"nofollow\"\u003eHERE\u003c\/a\u003e) to determine the right capacity for your home.\u003c\/p\u003e \u003chr\u003e \u003ch2\u003eIncluded in Your Order:\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eOutdoor Unit:\u003c\/strong\u003e ACIQ-36-EHPD Inverter Condenser (36,000 BTU)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eIndoor Unit:\u003c\/strong\u003e ACIQ-36-AHD Central Ducted Air Handler (36,000 BTU)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eInstallation Kit\u003c\/strong\u003e (optional, sold separately)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCompatible with any 24 V thermostat\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOwner’s \u0026amp; Service Manuals\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e \u003ch2\u003eKey Features:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eVariable-speed inverter twin-rotary compressor\u003c\/li\u003e \u003cli\u003eLearning condenser with advanced sensor suite\u003c\/li\u003e \u003cli\u003eMulti-positional DC-blower air handler\u003c\/li\u003e \u003cli\u003eSoft-start technology for reduced peak demand\u003c\/li\u003e \u003cli\u003eSelf-diagnostic control board with fault display\u003c\/li\u003e \u003cli\u003eQuiet operation: 63 dBA outdoor, up to 48 dBA indoor\u003c\/li\u003e \u003cli\u003eOptional electric heat kit available\u003c\/li\u003e \u003cli\u003eGold-fin coil for corrosion resistance\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003ch3\u003eACIQ-36-EHPD (Condenser)\u003c\/h3\u003e \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel Number\u003c\/td\u003e \u003ctd\u003eACIQ-36-EHPD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Cooling BTU\u003c\/td\u003e \u003ctd\u003e36,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Heating BTU\u003c\/td\u003e \u003ctd\u003e36,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSEER2 \/ HSPF2\u003c\/td\u003e \u003ctd\u003e16.1 \/ 8.7\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRefrigerant\u003c\/td\u003e \u003ctd\u003eR454B\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eElectrical\u003c\/td\u003e \u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax Breaker\u003c\/td\u003e \u003ctd\u003e30 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMin Breaker\u003c\/td\u003e \u003ctd\u003e27 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating Temp (Cooling)\u003c\/td\u003e \u003ctd\u003e–13 °F to 122 °F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating Temp (Heating)\u003c\/td\u003e \u003ctd\u003e–13 °F to 75 °F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLiquid\/Suction Valve\u003c\/td\u003e \u003ctd\u003e3\/8″ \/ 3\/4″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003ePre-charge Lineset\u003c\/td\u003e \u003ctd\u003e25′\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e163.58 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eACIQ-36-AHD (Air Handler)\u003c\/h3\u003e \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel Number\u003c\/td\u003e \u003ctd\u003eACIQ-36-AHD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAirflow\u003c\/td\u003e \u003ctd\u003eUp to 1,189 CFM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDecibel Level\u003c\/td\u003e \u003ctd\u003eUp to 48 dBA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eElectrical\u003c\/td\u003e \u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax Breaker\u003c\/td\u003e \u003ctd\u003e15 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMin Breaker\u003c\/td\u003e \u003ctd\u003e8 \/ 6 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e \u003ctd\u003e49″ × 21″ × 21″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e153.88 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eConfiguration\u003c\/td\u003e \u003ctd\u003eMulti-positional\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRefrigerant\u003c\/td\u003e \u003ctd\u003eR454B\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003chr\u003e \u003ch2\u003eWarranty Information\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e12 Year Compressor Limited Warranty (online registration required)\u003c\/li\u003e \u003cli\u003e7 Year Parts Limited Warranty (online registration required)\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch2\u003eManuals \u0026amp; Downloads\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-EHPD-Install-Manual.pdf\"\u003e EHPD Installation Manual \u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-EHPD-Service-Manual.pdf\"\u003e EHPD Service Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-AHD-EHPD-HPD-Nominal-Capacity-Performance-Chart-040825-PDF-1.pdf\"\u003e EHPD Heating\/Cooling Performance Chart \u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/AHD-Install-Manual.pdf\"\u003e AHD Installation Manual \u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/AHD-Owners-Manual.pdf\"\u003e AHD Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/EHPD-AHD-3Ton-Submittal.pdf\"\u003e 3 Ton EHPD\/AHD Submittal Data Sheet \u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-AHD-3Ton-Submittal.pdf\"\u003e 3 Ton HPD\/AHD Submittal Data Sheet \u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e \u003chr\u003e","brand":"ACiQ","offers":[{"title":"None","offer_id":53351133774137,"sku":"ACIQ-36-EHPD + ACIQ-36-AHD","price":4448.0,"currency_code":"USD","in_stock":false},{"title":"30 Ft","offer_id":53351133806905,"sku":"ACIQ-36-EHPD + ACIQ-36-AHD + LS38343830","price":4794.0,"currency_code":"USD","in_stock":false},{"title":"50 Ft","offer_id":53351133839673,"sku":"ACIQ-36-EHPD + ACIQ-36-AHD + LS38343850","price":4882.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0292\/1336\/0188\/files\/aciqpump.jpg?v=1780346530","url":"https:\/\/chillminisplits.com\/products\/aciq-3-ton-36-000-btu-16-1-seer2-high-efficiency-central-heat-pump-inverter-r454b-3-ton-36-000-btu-central-ducted-air-handler-r454b","provider":"Chill Mini Splits","version":"1.0","type":"link"}