{"product_id":"aciq-5-ton-60-000-btu-15-2-seer2-high-efficiency-central-heat-pump-inverter-r454b-5-ton-60-000-btu-central-ducted-air-handler-r454b","title":"ACiQ 5 Ton (60,000 BTU) 15.2 SEER2 High Efficiency Central Heat Pump | Inverter – R454B \u0026 5 Ton (60,000 BTU) Central Ducted Air Handler – R454B","description":"\u003ch1\u003eACiQ 5 Ton (60,000 BTU) 15.2 SEER2 High Efficiency Central Heat Pump | Inverter – R454B \u0026amp; 5 Ton (60,000 BTU) Central Ducted Air Handler – R454B\u003c\/h1\u003e \u003chr\u003e \u003ch2\u003eOverview\u003c\/h2\u003e \u003cp\u003eACiQ's High-Efficiency 5 Ton Heat Pump System pairs the robust ACIQ-60-EHPD inverter condenser with the versatile ACIQ-60-AHD multi-positional air handler to deliver precise, efficient heating and cooling through your existing ductwork. Variable-speed inverter technology lets the compressor modulate its output between 12,000 and 54,000 BTU to exactly match demand—eliminating short-cycling and cutting energy waste.\u003c\/p\u003e \u003cp\u003eOn first startup, the “learning condenser” enters sensor-driven learning mode to collect indoor\/outdoor temperatures, duct pressures, and refrigerant data, then optimizes future operation for maximum efficiency. Rated for −13 °F to 122 °F in cooling and down to 5 °F in heating, it maintains quiet, reliable comfort even in extreme climates.\u003c\/p\u003e \u003cp\u003eBacked by a 12-year compressor warranty and 7-year parts coverage (online registration required), this whisper-quiet system (65 dBA outdoor, up to 56 dBA indoor) integrates with any 24 V thermostat and can be installed upflow, downflow, or horizontally.\u003c\/p\u003e \u003chr\u003e \u003ch2\u003eHow is it different from a traditional heat pump?\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e \u003cstrong\u003eVariable BTU inverter:\u003c\/strong\u003e automatically adjusts output from 12,000–54,000 BTU\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eSmart soft-start:\u003c\/strong\u003e reduces inrush current and energy waste\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eHeating-sized design:\u003c\/strong\u003e size for heat without short-cycling in cooling mode\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eCold-climate rating:\u003c\/strong\u003e efficient heating down to 5 °F outdoor\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch2\u003eQuick Facts\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eVariable output based on demand: 12,000–54,000 BTU (cooling \u0026amp; heating)\u003c\/li\u003e \u003cli\u003eRefrigerant: R454B\u003c\/li\u003e \u003cli\u003eSEER2 \/ HSPF2: 15.2 \/ 8.4\u003c\/li\u003e \u003cli\u003eOperating range: −13 °F to 122 °F (cooling); −13 °F to 75 °F (heating)\u003c\/li\u003e \u003cli\u003eDurable gold-fin coil coating\u003c\/li\u003e \u003cli\u003eQuiet operation under full load\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eUse our sizing calculator (\u003ca href=\"\/pages\/hvac-load-calculator\" rel=\"nofollow\"\u003eHERE\u003c\/a\u003e) to determine the right capacity for your home.\u003c\/p\u003e \u003chr\u003e \u003ch2\u003eIncluded in Your Order:\u003c\/h2\u003e \u003cp\u003e\u003cstrong\u003eOutdoor Unit:\u003c\/strong\u003e ACIQ-60-EHPD Inverter Condenser (60,000 BTU)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eIndoor Unit:\u003c\/strong\u003e ACIQ-60-AHD Central Ducted Air Handler (60,000 BTU)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eInstallation Kit\u003c\/strong\u003e (optional, sold separately)\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eCompatible with any 24 V thermostat\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eOwner’s \u0026amp; Service Manuals\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e \u003ch2\u003eKey Features:\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eVariable-speed inverter twin-rotary compressor\u003c\/li\u003e \u003cli\u003eLearning condenser with advanced sensor suite\u003c\/li\u003e \u003cli\u003eMulti-positional DC-blower air handler\u003c\/li\u003e \u003cli\u003eSoft-start technology for reduced peak demand\u003c\/li\u003e \u003cli\u003eSelf-diagnostic control board with fault display\u003c\/li\u003e \u003cli\u003eQuiet operation: 65 dBA outdoor, up to 56 dBA indoor\u003c\/li\u003e \u003cli\u003eOptional electric heat kit available\u003c\/li\u003e \u003cli\u003eGold-fin coil for corrosion resistance\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch2\u003eTechnical Specifications\u003c\/h2\u003e \u003ch3\u003eACIQ-60-EHPD (Condenser)\u003c\/h3\u003e \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel Number\u003c\/td\u003e \u003ctd\u003eACIQ-60-EHPD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Cooling BTU\u003c\/td\u003e \u003ctd\u003e57,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRated Heating BTU\u003c\/td\u003e \u003ctd\u003e60,000\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eSEER2 \/ HSPF2\u003c\/td\u003e \u003ctd\u003e15.2 \/ 8.4\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRefrigerant\u003c\/td\u003e \u003ctd\u003eR454B\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eElectrical\u003c\/td\u003e \u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax Breaker\u003c\/td\u003e \u003ctd\u003e40 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMin Breaker\u003c\/td\u003e \u003ctd\u003e39 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating Temp (Cooling)\u003c\/td\u003e \u003ctd\u003e–13 °F to 122 °F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eOperating Temp (Heating)\u003c\/td\u003e \u003ctd\u003e–13 °F to 75 °F\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eLiquid\/Suction Valve\u003c\/td\u003e \u003ctd\u003e3\/8″ \/ 3\/4″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e224.21 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003ch3\u003eACIQ-60-AHD (Air Handler)\u003c\/h3\u003e \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth\u003eSpecification\u003c\/th\u003e \u003cth\u003eDetails\u003c\/th\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eModel Number\u003c\/td\u003e \u003ctd\u003eACIQ-60-AHD\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eAirflow\u003c\/td\u003e \u003ctd\u003eUp to 1,807 CFM\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDecibel Level\u003c\/td\u003e \u003ctd\u003eUp to 56 dBA\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eElectrical\u003c\/td\u003e \u003ctd\u003e208\/230 V, 1-Phase, 60 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMax Breaker\u003c\/td\u003e \u003ctd\u003e15 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eMin Breaker\u003c\/td\u003e \u003ctd\u003e11 \/ 14.5 Amps\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e \u003ctd\u003e53″ × 24.5″ × 21″\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eWeight\u003c\/td\u003e \u003ctd\u003e190.92 lbs\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eConfiguration\u003c\/td\u003e \u003ctd\u003eMulti-positional\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003eRefrigerant\u003c\/td\u003e \u003ctd\u003eR454B\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003chr\u003e \u003ch2\u003eWarranty Information\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e12 Year Compressor Limited Warranty (online registration required)\u003c\/li\u003e \u003cli\u003e7 Year Parts Limited Warranty (online registration required)\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003ch2\u003eManuals \u0026amp; Downloads\u003c\/h2\u003e \u003cul\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-EHPD-Install-Manual.pdf\"\u003eEHPD Installation Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/HPD-EHPD-Service-Manual.pdf\"\u003eEHPD Service Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/ACiQ-AHD-EHPD-HPD-Nominal-Capacity-Performance-Chart-040825-PDF-1.pdf\"\u003eNominal Capacity Performance Chart\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/AHD-Install-Manual.pdf\"\u003eAHD Installation Manual\u003c\/a\u003e\u003c\/li\u003e \u003cli\u003e\u003ca href=\"https:\/\/hvacdirect.com\/media\/pdf\/AHD-Owners-Manual.pdf\"\u003eAHD Owner’s Manual\u003c\/a\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e","brand":"ACiQ","offers":[{"title":"None","offer_id":53351133872441,"sku":"ACIQ-60-EHPD + ACIQ-60-AHD-1","price":5844.0,"currency_code":"USD","in_stock":false},{"title":"30 Ft","offer_id":53351133905209,"sku":"ACIQ-60-EHPD + ACIQ-60-AHD-2","price":6225.0,"currency_code":"USD","in_stock":false},{"title":"50 Ft","offer_id":53351133937977,"sku":"ACIQ-60-EHPD + ACIQ-60-AHD-3","price":6313.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0292\/1336\/0188\/files\/aciqpump_76bbbcac-4aa5-4bba-91df-442fb094200f.jpg?v=1780346530","url":"https:\/\/chillminisplits.com\/products\/aciq-5-ton-60-000-btu-15-2-seer2-high-efficiency-central-heat-pump-inverter-r454b-5-ton-60-000-btu-central-ducted-air-handler-r454b","provider":"Chill Mini Splits","version":"1.0","type":"link"}