Quick answer: which MRCOOL line is right for you?
For a DIY install, the MRCOOL DIY 5th Gen comes in 9K to 36K and the DIY Hyper Heat heats to -22°F. Easy Pro and DIY Select ship with a shorter 11.5 ft line set and lower SEER2. For a pro install, the Olympus E Star has the top SEER2 here, 27.4 at 9K, and heats to -22°F. For 2 to 6 rooms on one outdoor unit, the DIY 5th Gen Multi-Zone runs 18K to 55K.
This page puts MRCOOL's 2026 single zone and multi-zone mini split lines into small, sourced tables. Each number comes from an MRCOOL catalog, manual, submittal sheet or warranty, or from the NEEP cold climate heat pump list, which carries AHRI certificate numbers. When a spec is not published, the table says so. When we did the math ourselves, we say that too.
Start with who will install it. Five lines are built for a homeowner install with precharged QuickConnect line sets: DIY Select, DIY Easy Pro, DIY 5th Gen, DIY 5th Gen Hyper Heat and DIY 5th Gen Multi-Zone. Three lines are made for a pro install with flare connections: Advantage 5th Gen, Olympus E Star and Olympus Multi-Zone. Then check your winters, your sizes and the warranty. For a closer look at two lines, see our Easy Pro vs 5th Gen DIY guide and our MRCOOL DIY vs Olympus E Star comparison.
MRCOOL lineup at a glance
One row per line. Ranges cover every size in that line. Each line name links to its Chill collection.
| Line | Install type | BTU sizes | Zones | SEER2 | HSPF2 (Region IV) | Lowest heating temp | Voltage | Base warranty |
|---|---|---|---|---|---|---|---|---|
| MRCOOL DIY Select | DIY | 9K, 12K, 18K, 24K | 1 | 16.5 to 17.5 | 8.3 to 9 | 5°F | 115V (9K, 12K), 208/230V (18K, 24K) | 1 yr parts, 2 yr compressor |
| MRCOOL DIY Easy Pro | DIY | 9K, 12K, 18K, 24K | 1 | 18.9 to 20.2 | 8.5 to 9.3 | -13°F | 115V (9K, 12K), 208/230V (18K, 24K) | 3 yr parts, 5 yr compressor |
| MRCOOL DIY 5th Gen | DIY | 9K, 12K, 18K, 24K, 36K | 1 | 18 to 23.6 | 8.5 to 11.5 | -13°F | 115V (9K, 12K), 208/230V (18K to 36K) | 5 yr parts, 7 yr compressor |
| MRCOOL DIY 5th Gen Hyper Heat | DIY | 12K, 18K | 1 | 21.2 to 23.5 | 10 to 11 | -22°F | 208/230V | 5 yr parts, 7 yr compressor |
| MRCOOL DIY 5th Gen Multi-Zone | DIY | 18K, 27K, 36K, 48K, 55K outdoor | 2 to 6 | 21.8 to 23.9 | 9.5 to 10.6 | -13°F (18K to 48K), -22°F (55K) | 208/230V | 5 yr parts, 7 yr compressor |
| MRCOOL Advantage 5th Gen | Pro install | 9K, 12K, 18K, 24K, 36K | 1 | 18 to 21.5 | 8.5 to 9.6 | 5°F (9K to 24K), -13°F (36K) | 115V or 208/230V (9K, 12K), 208/230V (18K to 36K) | 1 yr parts, 2 yr compressor |
| MRCOOL Olympus E Star | Pro install | 9K, 12K, 18K, 24K | 1 | 21 to 27.4 | 10.5 to 13.5 | -22°F | 208/230V | 5 yr parts, 7 yr compressor |
| MRCOOL Olympus Multi-Zone | Pro install | 18K, 27K, 36K, 48K outdoor | Up to 6 | 24 to 25.1 | 9.5 to 10.3 | -13°F | 208/230V | 5 yr parts, 7 yr compressor |
| MRCOOL Universal | Central ducted heat pump | Not a mini split, so it is not in these tables. See our Universal vs Hyper Heat vs VersaPro guide. | ||||||
| MRCOOL VersaPro | Central ducted heat pump | Not a mini split, so it is not in these tables. See our Universal vs Hyper Heat vs VersaPro guide. | ||||||
Sources: MRCOOL 2026 product catalog, MRCOOL install manuals, submittal sheets and limited warranties, and the NEEP cold climate heat pump list. Full source list and AHRI numbers are in the CSV below. Last verified: November 23, 2026.
Which MRCOOL mini splits can you really install yourself?
The five DIY lines use precharged QuickConnect line sets. MRCOOL brochures say these install without a vacuum pump or gauges. The DIY single zone manuals list a 75 ft maximum line set run. If you need more than the included line set, you join precharged sets with a coupler. Our line set length guide walks through measuring your run, and our what comes with a MRCOOL DIY mini split checklist covers the rest of the box.
The pro lines use flare connections. Their submittal sheets list longer maximum piping lengths, and the factory charge covers 24.6 ft of line on the Advantage and E Star. Longer runs need added refrigerant, so a licensed tech should handle them.
| Line | Installer | Line set | Max line set run | Max height difference | Voltage |
|---|---|---|---|---|---|
| MRCOOL DIY Select | DIY | 11.5 ft precharged QuickConnect, included | 75 ft total | 49.2 ft (9K and 12K), 65.6 ft (18K), 75 ft (24K) | 115V (9K, 12K), 208/230V (18K, 24K) |
| MRCOOL DIY Easy Pro | DIY | 11.5 ft precharged QuickConnect, included | 75 ft total | 49.2 ft (9K and 12K), 65.6 ft (18K), 75 ft (24K) | 115V (9K, 12K), 208/230V (18K, 24K) |
| MRCOOL DIY 5th Gen | DIY | 25 ft precharged QuickConnect, included | 75 ft total | 49.2 ft (9K and 12K), 65.6 ft (18K), 75 ft (24K and 36K) | 115V (9K, 12K), 208/230V (18K to 36K) |
| MRCOOL DIY 5th Gen Hyper Heat | DIY | Precharged QuickConnect, included | 75 ft total | 49.2 ft (12K), 65.6 ft (18K) | 208/230V |
| MRCOOL DIY 5th Gen Multi-Zone | DIY | QuickConnect compatible, one line set per indoor unit | 75 ft per indoor unit; 172 ft total (18K), 221 ft total (27K to 55K) | 24 ft between indoor units. Indoor to outdoor: Not published | 208/230V |
| MRCOOL Advantage 5th Gen | Pro install | 16 ft install kit included, flare connections | 82 ft (9K and 12K, both voltages), 98.4 ft (18K), 164 ft (24K), 213.2 ft (36K) | 49.2 ft (9K and 12K, both voltages), 65.6 ft (18K), 82 ft (24K), 98.4 ft (36K) | 115V or 208/230V (9K, 12K), 208/230V (18K to 36K) |
| MRCOOL Olympus E Star | Pro install | Flare connections, line set sold separately | 82 ft (9K and 12K), 98.4 ft (18K), 164 ft (24K) | 49.2 ft (9K and 12K), 65.6 ft (18K), 82 ft (24K) | 208/230V |
| MRCOOL Olympus Multi-Zone | Pro install | Flare connections, line sets sold separately | 98.4 ft per indoor unit and 196.8 ft total (18K); 114.8 ft per indoor unit and 262.4 ft total (27K to 48K) | 49.2 ft | 208/230V |
Sources: MRCOOL install manuals (DIY Select, Easy Pro, DIY 5th Gen single zone, DIY Hyper Heat, DIY 5th Gen Multi-Zone), MRCOOL submittal sheets (Advantage, Olympus E Star, Olympus Multi-Zone), the Advantage brochure and the MRCOOL 2026 product catalog. Last verified: November 23, 2026.
Which MRCOOL line heats best in cold weather?
Two numbers matter. The first is the lowest outdoor temperature where the system still heats. The second is how much heat it puts out at 5°F. NEEP publishes the 5°F number for most of these systems.
DIY Hyper Heat and Olympus E Star list heating down to -22°F. Easy Pro, DIY 5th Gen and both multi-zone lines list -13°F, except the DIY Multi-Zone 55K, which lists -22°F. DIY Select heats down to 5°F. In NEEP's data, the DIY Hyper Heat 18K and the E Star 18K both put out their full 18,000 BTU/h at 5°F. By our math, the other systems keep 52% to 96% of their rated heat at 5°F. Our guide to mini splits below zero explains how to plan for cold snaps.
| Line | Lowest heating temp | Max heat at 5°F (BTU/h) | Heat kept at 5°F (our calculation) |
|---|---|---|---|
| MRCOOL DIY Select | 5°F | 9K: 6,000 12K: 6,200 18K: 9,500 24K: Not published |
52% to 67% |
| MRCOOL DIY Easy Pro | -13°F | 9K: 6,200 12K: 6,700 18K: 9,800 24K: 17,000 |
54% to 68% |
| MRCOOL DIY 5th Gen | -13°F | 9K: 7,300 12K: 8,400 18K: 12,800 24K: 16,100 36K: 22,000 |
61% to 73% |
| MRCOOL DIY 5th Gen Hyper Heat | -22°F | 12K: 11,000 18K: 18,000 |
92% to 100% |
| MRCOOL DIY 5th Gen Multi-Zone | -13°F (18K to 48K), -22°F (55K) | 18K: 13,300 27K: 18,200 36K: 25,200 48K: 37,000 55K: 46,000 |
70% to 84% |
| MRCOOL Advantage 5th Gen | 5°F (9K to 24K), -13°F (36K) | 9K 115V: 6,500 9K 230V: 7,000 12K 115V: 6,600 12K 230V: 8,000 18K: 11,500 24K: 17,000 36K: 21,400 |
55% to 71% |
| MRCOOL Olympus E Star | -22°F | 9K: 11,500 12K: 11,500 18K: 18,000 24K: 24,200 |
83% to 100% |
| MRCOOL Olympus Multi-Zone | -13°F | 18K: 13,500 27K: 19,000 36K: 26,000 48K: 36,000 |
70% to 75% |
Sources: lowest heating temps from MRCOOL install manuals, the Easy Pro brochure and MRCOOL submittal sheets. The DIY Select 5°F limit is from Chill's DIY Select product pages (see the DIY Select collection). Max heat at 5°F from the NEEP cold climate heat pump list. Heat kept at 5°F is our own math: NEEP max heat at 5°F divided by NEEP rated heat at 47°F, rounded to the nearest whole percent, so it can read 1 point higher than NEEP's own capacity maintenance figure. Last verified: November 23, 2026.
How efficient is each MRCOOL line?
SEER2 rates cooling over a season. EER2 rates cooling on a hot day. HSPF2 rates heating over a season. Higher is better for all three. Our SEER2, EER2 and HSPF2 guide explains each one.
| Line | SEER2 | EER2 | HSPF2 (Region IV) |
|---|---|---|---|
| MRCOOL DIY Select | 9K: 17.5 12K: 17.5 18K: 17.3 24K: 16.5 |
9K: 9.8 12K: 8.5 18K: 9 24K: 8.6 |
9K: 8.8 12K: 9 18K: 8.5 24K: 8.3 |
| MRCOOL DIY Easy Pro | 9K: 20.2 12K: 19.5 18K: 20 24K: 18.9 |
9K: 11.3 12K: 9 18K: 9.8 24K: 9.7 |
9K: 9.2 12K: 9.3 18K: 8.5 24K: 8.7 |
| MRCOOL DIY 5th Gen | 9K: 23.6 12K: 23.5 18K: 22.5 24K: 22.7 36K: 18 |
9K: 14 12K: 12.5 18K: 13.7 24K: 12.7 36K: 8.5 |
9K: 11.5 12K: 10.2 18K: 11.5 24K: 9.5 36K: 8.5 |
| MRCOOL DIY 5th Gen Hyper Heat | 12K: 23.5 18K: 21.2 |
12K: 12.8 18K: 12.5 |
12K: 10 18K: 11 |
| MRCOOL DIY 5th Gen Multi-Zone | 18K: 23.9 27K: 23 36K: 23 48K: 21.8 55K: 22 |
18K: 13 27K: 12 36K: 12 48K: 12 55K: 12 |
18K: 10 27K: 9.5 (NEEP lists 9.0) 36K: 9.9 48K: 10 55K: 10.6 |
| MRCOOL Advantage 5th Gen | 9K 115V: 21.5 9K 230V: 21.2 12K 115V: 21.2 12K 230V: 21.3 18K: 19.2 24K: 18.7 36K: 18 |
9K 115V: 12.5 9K 230V: 12.6 12K 115V: 10.1 12K 230V: 10.8 18K: 10.8 24K: 10 36K: 9 |
9K 115V: 9 9K 230V: 9.1 12K 115V: 8.7 12K 230V: 9.1 18K: 9.6 24K: 9.3 36K: 8.5 |
| MRCOOL Olympus E Star | 9K: 27.4 12K: 25.4 18K: 21.4 24K: 21 |
9K: 15.4 12K: 13.4 18K: 12.5 24K: 13 |
9K: 12.5 12K: 10.5 18K: 11 24K: 13.5 |
| MRCOOL Olympus Multi-Zone | 18K: 25.1 27K: 25 36K: 24 48K: 24 |
18K: 14 27K: 13 36K: 12 48K: 12.5 |
18K: 9.8 27K: 9.5 36K: 9.5 48K: 10.3 |
Sources: MRCOOL 2026 product catalog and the NEEP cold climate heat pump list. Full source list and AHRI numbers are in the CSV below. Last verified: November 23, 2026. Note: for the DIY Multi-Zone 27K with all non-ducted indoor units, MRCOOL's catalog lists 9.5 HSPF2 and NEEP lists 9.0.
What sizes and zone setups does each line come in?
Single zone systems pair one outdoor unit with one indoor unit. Multi-zone systems run 2 or more indoor units from one outdoor unit. Size each room first with our BTU sizing guide. For a whole home, run our free Manual J calculator.
| Line | BTU sizes | Zones | Notes |
|---|---|---|---|
| MRCOOL DIY Select | 9K, 12K, 18K, 24K | 1 | Single zone, wall mount |
| MRCOOL DIY Easy Pro | 9K, 12K, 18K, 24K | 1 | Single zone, wall mount |
| MRCOOL DIY 5th Gen | 9K, 12K, 18K, 24K, 36K | 1 | Single zone. Ratings shown are for the wall mount pairing |
| MRCOOL DIY 5th Gen Hyper Heat | 12K, 18K | 1 | Single zone. Ratings shown are for the wall mount pairing |
| MRCOOL DIY 5th Gen Multi-Zone | 18K, 27K, 36K, 48K, 55K outdoor | Up to 3 (18K), 4 (27K), 5 (36K), 6 (48K and 55K) | Outdoor units pair with 6K to 36K indoor units |
| MRCOOL Advantage 5th Gen | 9K, 12K, 18K, 24K, 36K | 1 | Single zone, wall mount. 9K and 12K come in 115V and 230V |
| MRCOOL Olympus E Star | 9K, 12K, 18K, 24K | 1 | Single zone. Ratings shown are for the wall mount pairing |
| MRCOOL Olympus Multi-Zone | 18K, 27K, 36K, 48K outdoor | Up to 3 (18K), 4 (27K), 5 (36K), 6 (48K) | Wall mount, ceiling cassette and ceiling recessed indoor units in 9K to 24K |
Sources: MRCOOL 2026 product catalog (multi-zone pairing charts on pages 16 to 17). Full source list and AHRI numbers are in the CSV below. Last verified: November 23, 2026.
What warranty comes with each MRCOOL line?
These are the base terms printed in each MRCOOL limited warranty. Every one of them excludes labor. Our mini split warranty guide explains parts, compressor and labor coverage.
| Line | Parts | Compressor | Labor | Document |
|---|---|---|---|---|
| MRCOOL DIY Select | 1 year | 2 years | Not covered | DIY Select limited warranty |
| MRCOOL DIY Easy Pro | 3 years | 5 years | Not covered | Easy Pro limited warranty |
| MRCOOL DIY 5th Gen | 5 years | 7 years | Not covered | 5th Gen DIY limited warranty |
| MRCOOL DIY 5th Gen Hyper Heat | 5 years | 7 years | Not covered | 5th Gen DIY limited warranty |
| MRCOOL DIY 5th Gen Multi-Zone | 5 years | 7 years | Not covered | 5th Gen DIY limited warranty |
| MRCOOL Advantage 5th Gen | 1 year | 2 years | Not covered | Advantage limited warranty |
| MRCOOL Olympus E Star | 5 years | 7 years | Not covered | Olympus limited warranty |
| MRCOOL Olympus Multi-Zone | 5 years | 7 years | Not covered | Olympus limited warranty |
Sources: MRCOOL limited warranty documents for each series, page 1. Last verified: November 23, 2026.
How we built this table
- We pulled SEER2, EER2, HSPF2, sizes, zones and voltage from the MRCOOL 2026 product catalog.
- We pulled heating limits and line set limits from MRCOOL install manuals and submittal sheets.
- We pulled 47°F and 5°F heating output from the NEEP cold climate heat pump list. NEEP lists the AHRI certificate number for each system. Those numbers are in the CSV.
- Single zone ratings are for the wall mount pairing. Multi-zone ratings are for all non-ducted indoor units.
- MRCOOL's DIY Select documents do not list a heating limit. The 5°F figure comes from Chill's DIY Select product pages.
- When a spec is not in an MRCOOL document or NEEP, we wrote "Not published." We did not estimate.
- The "heat kept at 5°F" column is our own calculation.
- Chill still lists a few DIY 4th Gen units. MRCOOL's 2026 catalog covers the 5th Gen, so the 4th Gen is not in these tables.
- MRCOOL's DIY Hybrid Air Handler (ducted) and the OuttaSight ceiling cassette are not in these tables. Single zone ratings here are for the wall mount pairing.
- Last verified: November 23, 2026.
Download the data
Download the MRCOOL lineup spec table (CSV). It has one row per system, with the outdoor and indoor model numbers, every number in the tables above, the AHRI certificate number, a source for each row and a last verified date. You are welcome to use it. Please link back to this page.
FAQ
Which MRCOOL mini split heats at the lowest outdoor temperature?
The DIY 5th Gen Hyper Heat and the Olympus E Star (models ending in 230C-O1) list heating down to -22°F. The DIY 5th Gen Multi-Zone 55K also lists -22°F.
Which MRCOOL lines can I install myself?
DIY Select, DIY Easy Pro, DIY 5th Gen, DIY 5th Gen Hyper Heat and DIY 5th Gen Multi-Zone use precharged QuickConnect line sets. Advantage, Olympus E Star and Olympus Multi-Zone are pro install lines.
Which MRCOOL mini splits run on 115V?
The 9K and 12K sizes of DIY Select, DIY Easy Pro and DIY 5th Gen run on 115V. The Advantage 9K and 12K come in 115V or 230V. All other sizes in these tables run on 208/230V.
How long can a MRCOOL DIY line set be?
The DIY single zone manuals list a 75 ft maximum run. The DIY 5th Gen Multi-Zone manual lists 75 ft per indoor unit.
What is the warranty on the MRCOOL DIY Select?
MRCOOL's DIY Select warranty lists 1 year on parts and 2 years on the compressor. Labor is not covered.
Who do I call for help with a MRCOOL system that is not working?
Call MRCOOL tech support at 270-366-0457. Have your outdoor and indoor model numbers ready.