What Size Mini Split Do I Need for a Sunroom?

What Size Mini Split Do I Need for a Sunroom?

Quick answer: Most sunrooms need a 9K to 18K mini split. Start with the ENERGY STAR chart, then add for sun and glass. A 300 sq ft sunroom charts at 8,000 BTU, and with our rule of thumb it lands near a 12K. Mount the indoor unit on a solid wall, out of direct sunlight.

A sunroom is the best room in the house in spring. In winter it is often the coldest. All that glass loses heat fast, and in summer it lets in a lot of sun. A mini split can heat it in winter and cool it in summer. This guide covers the size to buy, where to mount it, and which models handle cold nights. For any other room, our mini split sizing guide explains the full method.

Sunroom mini split sizing infographic showing square feet, chart BTU, BTU with sun and glass added, and the MRCOOL DIY size to look at

What size mini split do I need for my sunroom?

Start with the square feet. Multiply the length of the room by its width. A sunroom that is 15 ft by 20 ft is 300 sq ft.

Next, find that size on the ENERGY STAR chart in our sizing guide. It lists 8,000 BTU for 300 up to 350 sq ft and 12,000 BTU for 450 up to 550 sq ft. That chart assumes a normal room with 8 ft ceilings.

A sunroom is not a normal room. ENERGY STAR says to add 10% for a very sunny room. Our calculator's rule of thumb adds 10% to 20% more for poor insulation, and it names sunrooms as one of those spaces. Put together, our rule of thumb for a sunroom is to add about 20% to 30% to the chart number.

Here is the math for a 300 sq ft sunroom: 8,000 BTU plus 20% to 30% is about 9,600 to 10,400 BTU. That is more than a 9K, so a 12K is the size to look at.

Sunroom size chart: which MRCOOL DIY size fits?

Sunroom size Chart BTU (ENERGY STAR) With sun and glass added (our math, +20% to 30%) MRCOOL DIY size to look at
150 to 250 sq ft 6,000 7,200 to 7,800 9K
250 to 350 sq ft 7,000 to 8,000 8,400 to 10,400 9K or 12K
350 to 450 sq ft 9,000 to 10,000 10,800 to 13,000 12K, or 18K for lots of glass
450 to 550 sq ft 12,000 14,400 to 15,600 18K
550 to 700 sq ft 14,000 16,800 to 18,200 18K or 24K

Sources: ENERGY STAR chart as shown in our sizing guide. The 10% sun add is from ENERGY STAR. The 10% to 20% insulation add is our calculator's rule of thumb. The added BTU column and the size picks are our own math.

Have a tall or sloped ceiling? Our calculator's rule of thumb adds about 10% for each foot above 8 ft. For a sunroom that is part of the main living space, run our free Manual J calculator. For a quick number for one room, try the mini split sizing calculator.

Which MRCOOL DIY system fits a sunroom?

MRCOOL lists an "up to" coverage for each size. These are best case numbers, so a glassy room may need the next size up.

Not sure if your sunroom has the right outlet or breaker? Our 115V vs 230V guide explains the difference.

Where should a mini split go in a sunroom?

This is the step most sunroom buyers miss. MRCOOL's 5th Gen DIY manual says not to install the indoor unit in a spot that gets direct sunlight. It also says not to put it near a doorway or near any source of heat.

In a sunroom, that usually means the wall you share with the house. It is solid, and it tends to get less direct sun than the glass walls. The manual also calls for these clearances around a wall unit:

  • At least 5.9 ft from the floor to the bottom of the unit
  • At least 5.9 inches from the top of the unit to the ceiling
  • At least 4.72 inches on each side

Keep the unit away from the patio door, too. Our mini split placement guide walks through more spots to avoid.

Does your sunroom have no good wall? A ceiling cassette mounts in the ceiling instead. The MRCOOL DIY 12K Hyper Heat ceiling cassette system is one option. Many sunrooms have sloped or glass roofs, so read our ceiling cassette fit checklist before you buy one.

Will a mini split heat a sunroom in winter?

Yes. A mini split is a heat pump, so it heats as well as cools. MRCOOL's manual lists heat mode for room temperatures from 32°F to 86°F. The standard 5th Gen heats in outdoor temperatures down to -13°F, per its Chill product pages.

Live where winters get very cold? The MRCOOL DIY Hyper Heat systems heat down to -22°F, per their Chill product pages. The MRCOOL DIY 12K Hyper Heat runs on 230V and lists coverage up to 600 sq ft. Our cold climate comparison shows how Hyper Heat stacks up against the standard 5th Gen.

How do I get the most out of a sunroom mini split?

Glass works against you in both seasons. MRCOOL's own tips help:

  • Close the windows and doors. MRCOOL lists open doors and windows as a cause of poor heating and poor cooling.
  • Use blinds or curtains on hot days. MRCOOL says to close windows and curtains during high heat or bright sunshine.
  • Pick a steady setting. Our guide to the best mini split temperature covers winter and summer settings.

Still shopping?

See every size in our MRCOOL DIY 5th Gen mini splits collection, or check the Hyper Heat systems above. Want help matching a system to your sunroom? Call Chill Mini Splits at (888) 231-8920.

FAQ

What size mini split do I need for a 300 sq ft sunroom?

A 12K is a good place to start. The ENERGY STAR chart lists 8,000 BTU for 300 up to 350 sq ft. With our rule of thumb of adding 20% to 30% for sun and glass, that comes to about 9,600 to 10,400 BTU.

What size mini split do I need for a 500 sq ft sunroom?

Look at an 18K. The chart lists 12,000 BTU for 450 up to 550 sq ft. With our sun and glass add, that comes to about 14,400 to 15,600 BTU, which is more than a 12K.

Can a mini split go on a sunroom wall that gets sun?

MRCOOL's manual says not to install the indoor unit where it gets direct sunlight. The wall you share with the house is often the best choice. A ceiling cassette is another option.

Will a mini split keep a sunroom warm in winter?

Yes, it is a heat pump. The standard MRCOOL DIY 5th Gen heats down to -13°F outside. The Hyper Heat models heat down to -22°F, per their Chill product pages.

Do I need a bigger mini split for a sunroom than a regular room?

Usually, yes. ENERGY STAR adds 10% for a very sunny room. Our calculator's rule of thumb adds 10% to 20% more for poor insulation, and sunrooms are one of the spaces it names.

Should I get a 115V or 230V mini split for a sunroom?

It depends on the size and what your panel can support. The MRCOOL DIY 9K and 12K 5th Gen run on 115V. The 18K and the Hyper Heat systems run on 230V.

Who can answer install questions about my MRCOOL unit?

MRCOOL tech support can help with install and setup questions at 270-366-0457. You can also find the full install manual on MRCOOL's site.

Ready to size your system?

Use the calculator for a quick match, or build a complete multi-room system with live pricing.